Register Register Login   Sign out +44-203-4681833
Home / Products / CONTROLLER & SENSOR / Conductivity / innoCon 6800C Conductivity / Resistivity/ TDS Measurement

innoCon 6800C Conductivity / Resistivity/ TDS Measurement

innoCon 6800C controller is specially designed for water treatment and industrial process control. Used with innoSens 310/330 sensor, it can measure the conductivity,resistivity,TDS and temperature of the sample water. It features automatic temperature compensation and has various mounting methods. 4-20mA/RS485 and multiple control function outputs are a standard feature.

 

Application

Process Water, Drinking Water, Cooling Water, Wastewater Treatment

 

Technical Data

Measuring parameter

Conductivity:

0.00 - 20.00 /200.0/2000 μS/cm

0.00 - 20.00 /200.0/2000 mS/cm

Resistivity0.00-20.00 MΩ/cm

TDS 0.00 ppm-200.0 ppt

 

Features

  • The latest wide power input, super anti-interference design

  • Flame retardant plastic bite shell, better texture feel

  • Large-screen backlit LCD shows measured values, temperature and relay status

  • C hinese / English menu, easier to operate

  • Password protection, to prevent unauthorized operation

  • New calibration steps can help reduce operational errors

  • NEMA4X / IP65 protection class, a variety of installation methods

  • 2 sets relay output can set High/ Low

  • Automatic cleaning relay output

  • 2 channel 4-20mA current / RS485 Modbus output

  • One key to restore factory settings


Features

Technical Data

Measurement parameter

 

Conductivity:0.00-2000mS/cm

Resistivity: 0-20.00MΩ*cm

TDS: 0-99900ppm

Input

 

Measuring sensor: innoSens 710 potentiostatic sensor

Temperature probe: Pt-1000 / NTC-10K (optional)

Output

Analog Output 1: 4-20 mA isolated current output for Cl2/ ClO2/O3/(or it can be made to represent any segment of the measuring scale)  Load: Max 600Ω

Analog Output 2: 4-20 mA isolated current output for TEMP.(it can be made to represent any segment of the measuring scale)  Load: Max 600Ω

Relay 1&2 (Alarm)

Operation: ON/OFF

Selectable action : High / Low

Set Point: High/10.00mg/L; Low/4.00mg/L (adjustable)

Hysteresis: 0.10mg/L (adjustable)

Relay contacts: 5A/250VAC;5A/30VDC

Relay 3

(Washing Relay)

 

Wash interval: 0.1~1000hour

Wash time: 1~1000s

Relay contacts: 5A/250VAC;5A/30VDC

Interface

RS 485 Modbus RTU

Baud rate: 9600 bps

Data format: 8 bit

General Information

Power supply

90 - 260V AC, 50/60Hz; 24VDC(Optional)

Operating temperature

 0 - 60 ℃

Storage temperature

-20 - 70 ℃

Humidity

Max. 90% rH at 40℃ (non-condensing)

LCD Screen

Big-size screen of crystal display, white back light

Language

Chinese / English

Passcode

Set mode: 0022, Calibration mode: 0011

Protection grade

 IP65

Dimensions

144 * 144 * 110mm

Installation

Wall/Pipe/Panel Mounting

Panel Cut Size

138 * 138mm

Weight

0.85Kg

 


specifications

Order Guide

 

Conductivity / Resistivity / TDS Controller            

           

Order No.

Type

Descriptions

33-6801-20

innoCon 6800C

Conductivity Controller, 90 - 260V AC

33-6801-24

innoCon 6800C

Conductivity Controller, 24V DC

35-0320-01

innoSens 320

Conductivity Sensor, K=0.01, 0-20.00μS/cm, 5m cable

35-0320-02

innoSens 320

Conductivity Sensor, K=0.1, 0-200.0μS/cm, 5m cable

35-0320-03

innoSens 320

Conductivity Sensor, K=1,0-2000μS/cm, 5m cable

35-0330-00

innoSens 330

Conductivity / Resistivity / TDS Sensor,10μS/cm ~ 200.0 mS/cm, 5m cable

download

6800C

QUESTIONS? WE'RE HERE TO HELP.

CONTACT US
Search